1000 V Bidirectional DC Power Supply

Battery Simulator DC Power Supply

1000 V bidirectional, regenerative, programmable DC power supply. 1000 V class for high-voltage EV packs, ESS strings and DC fast charging. Source and sink in one unit, with energy regenerated to the grid at up to 93%.

Bidirectional93% regen≤5 ms0.02% F.S.CC/CV/CP/CRSCPI · Modbus · CANopen

Models in this class

Every model below is a bidirectional source + regenerative load. Request a quote on any configuration — or ask us to size a parallel system.

VoltageCurrentPowerFormModel
1000 V±65 A28 kW3UN35528-1000-65Quote →
1000 V±80 A32 kW3UN35532-1000-80Quote →
1000 V±80 A42 kW3UN35542-1000-80Quote →
1000 V±130 A56 kW6UN35556-1000-130Quote →
1000 V±195 A84 kW22UN35584-1000-195Quote →
1000 V±260 A112 kW22UN355112-1000-260Quote →
1000 V±325 A140 kW32UN355140-1000-325Quote →
1000 V±390 A168 kW32UN355168-1000-390Quote →
1000 V±455 A196 kW32UN355196-1000-455Quote →
1000 V±520 A224 kW42UN355224-1000-520Quote →
1000 V±585 A252 kW42UN355252-1000-585Quote →
1000 V±650 A280 kW42UN355280-1000-650Quote →

View & quote this product page →

Capabilities

Bidirectional source + regenerative load, plus optional battery simulation (NS81000, 7 model libraries + custom curves) and PV array simulation (NS91000, EN50530 / Sandia static & dynamic MPPT).

Technical specifications

Technical specifications (representative)
Output voltage range0 – rated (360 / 500 / 750 / 1000 / 1500 / 2250 V)
Output currentBidirectional ± rated (to 240 A / unit, to 2400 A in cabinet)
Output powerBidirectional ± rated (14 kW–420 kW; MW via parallel)
Operating quadrantsDual-quadrant (source + regenerative sink), seamless crossover
Regenerative efficiencyUp to 93% (energy returned to grid)
CV setting accuracy≤ 0.02% + 0.02% F.S.
CC / CP setting accuracy≤ 0.1% + 0.1% F.S.
Voltage readback accuracy≤ 0.02% + 0.02% F.S.
Dynamic responseVoltage rise/fall ≤ 5 ms (representative 3U); transient recovery < 4.5 ms (10→60%)
Load modesCC / CV / CP / CR, with CC&CV priority
SimulationBattery (NS81000, 7 libraries + custom) · PV I-V/P-V (NS91000, EN50530/Sandia)
ProtectionsOVP / OCP / OPP / UVP / UCP
Power factor0.99
AC inputThree-phase 340–480 VAC, 47–63 Hz
InterfaceLAN / RS232 / RS485 / CAN — SCPI, Modbus-RTU, CANopen
Display6.8″ LCD
Operating environment0–50 °C (derate > 35 °C); storage −10–70 °C; < 2000 m; 5–90% RH non-condensing
Standards / qualityCE · IEC 61010-1 · ISO 17025-traceable calibration (on request)

Need this configured for your test?

Send voltage, power and application — get a quote with engineering support.

Request a Quote